How the sun, the wind, the batteries and the buildings fit together. The direction was set by the project owner in September 2026 and is a working basis, not final decisions.

Sunhome roofs and a shared plantWindevaluated, needs local measurementsBattery in every homewith local energy managementShared storageassessed for the whole fieldThe sand battery is droppedSmart control30 homeslow energy demand, simple south roofsThe office building19 offices today, 28 plannedWarehouse and workshopcounted as one home for nowThe gridordinary connection, microgrid under studysurplus is sold, shortfall is boughtSunhome roofs anda shared plantWindevaluated, needslocal measurementsBattery inevery homewith local energymanagementShared storageassessed for thewhole fieldThe sand batteryis droppedSmart control30 homeslow energy demand, simple south roofsThe office building19 offices today, 28 plannedWarehouse and workshopcounted as one home for nowThe gridordinary connection, microgrid under studysurplus is sold, shortfall is bought
Measures assessed

What is in, and what is out

17 measures. The energy track compared 16 of them on cost, feasibility, robustness in a power cut and how much energy they give or save; the shared solar plant came later with the project owner's direction. The assessments are provisional, and the building standard for the homes is not set. Where the energy track and the project owner differ, both are given.

Comparison table from the energy track, 28 August 2026, direction from the project owner, 4 September 2026, and clarifications in the project, 27 September 2026. Robustness in a power cut is scored from 0 to 10.

The 17 measures, with the verdict and the robustness in a power cut
MeasureVerdictIn a power cut
Production
Rooftop solarYes, can cover much of the demand10 of 10
Shared solar plantDirection from the project owner, the figure must be computednot scored
Small windEnergy track: no. Project owner: evaluated as a supplement7 of 10
Storage and heat
Bedrock heatYes or maybe, storage or extraction to be settled0 of 10 on its own
Seasonal borehole storage (BTES)Yes or maybe0 of 10 on its own
Battery in every homeYes, can be expensive over time9 of 10
Shared emergency batteryYes or maybe10 of 10
Large shared batteryNo, legally demanding5 of 10
Sand batteryNo, dropped0 of 10 on its own
The building
Heat recovery ventilationYes, saves a lot of heat loss2 of 10
Air sealingYes, but the benefit depends on the power price10 of 10
Greywater heat recoveryYes, saves some energy8 of 10
Control
Smart load managementYes0 of 10
Energy display for residentsYes0 of 10
Local microgridDifficult, needs further study8 of 10
Car battery as storage (V2H)No, little benefit against cost10 of 10
Three-phase supplyNo, not needed0 of 10
Provisionalabout 720,000 kWhtotal energy demand a year for the homes, the office and the warehouse, with a realistic range of ±25 %
Provisional52.5 %power self-sufficiency in the working version of the energy budget. Expected to fall once the solar output is corrected.
Provisional420 kWhtotal battery capacity, 14 kWh per home, one cycle a day.
Ground heat

The borehole field, simulated over 35 years

The energy track has simulated a borehole field in Earth Energy Designer, the most common tool for ground heat in Norway. The pictures are from the analysis.

Graph from Earth Energy Designer: the fluid temperature in the boreholes over 35 years. It settles, and in the last year it stays between -0.78 and 8.12 °C.
Temperature over 35 years The curve settles. In the last year the lowest fluid temperature is -0.78 °C and the highest 8.12 °C. The energy track judges both to be good.The energy track, Earth Energy Designer. Open the full picture
Earth Energy Designer, the base load dialog: heating 325 MWh and cooling 90 MWh a year spread over the months, hot water 80 MWh, net 288.33 MWh taken from the ground
Base load Heating 325 MWh a year, cooling 90 MWh, hot water 80 MWh with a seasonal factor of 3.0. Net heat taken from the ground: 288 MWh.The energy track, Earth Energy Designer. Open the full picture
Earth Energy Designer, the borehole and heat exchanger dialog: 28 boreholes in an open rectangle of 4 x 12, 105.83 m deep, 15 m apart, 110 mm, double U collector
The borehole field 28 boreholes in an open rectangle of 4 x 12, 106 metres deep, 15 metres apart, 110 mm across, with a double U collector.The energy track, Earth Energy Designer. Open the full picture
  • Wind power in the 50 to 250 kW class
  • Hybrid solar panels and solar collectors
  • Varden school in Bergen and Zero Village Bergen as reference projects
  • The TRNSYS and Winsun tools
What is studied next The energy track, 28 August 2026
Provisional243,567 kWhsolar power a year in the energy budget, which itself says the figure is about 30 % too high. The status summary estimates about 235,000 kWh from 1,350 m² of panels.
Provisionalabout 39,000 krestimated yearly saving per home against direct electric heating without solar or batteries, simplified split.
Provisionalabout 104,000 kgCO₂ saved a year against the reference, with 0.2 kg per kWh of grid power as the method's choice.
Provisional499,846 kWhheat a year from the bedrock plant: 325,000 kWh from the boreholes, with a seasonal factor of 3.6.
Provisional42,048 kWhwind power a year if it is built: 3 turbines of 8 kW at a capacity factor of 25 %. Needs a wind measurement on site.
Provisional2.10 kr/kWhpurchase price of power in the budget: a spot price of 2.00 kr, which the sheet calls very uncertain, plus 0.10 kr grid fee. Surplus sells for 0.75 kr/kWh.
From the project owner

The direction

The direction from the project owner, 4 September 2026. Not final decisions, but what is to be investigated now.

  1. Each home should have its own battery and energy management, with possible access to shared storage.
  2. A microgrid should be investigated at a limited level, but it should not be a prerequisite for the project.
  3. The sand battery should remain an option, but no major resources should be committed until the overall system is better defined. The sand battery has since been dropped.
  4. The workshop and storage building may provisionally be dimensioned as one home, clearly marked as an assumption.
  5. The office building should be estimated from actual consumption for the 19 completed offices, with an adjusted projection for 28 offices.
  6. The solar concept should combine optimised house surfaces with a shared installation, initially modelled at around 600 panels.
  7. Wind energy should be evaluated as a complementary source, based on local measurements.
  8. The aim is a robust, flexible and future-ready energy system, not a field built around a single technology.
Simulated hour by hour

The field through a whole year

The energy budget works month by month. Here the whole field is computed hour by hour through a typical year for Knotten, with weather from the EU's PVGIS, the panels of every house on its own roof and use as in the budget. Choose measures and see what they mean, and try a power cut.

The energy simulator: the field hour by hour through a year
Choose measures, press play or drag through the year. The figures are a model built on the energy budget and real data, not measurements.
Solar per homeSharedBattery per homePower price
Computing the year ...
12:00
Friday 21. March
Glowing panels: solar powerAmber: shared or soldBlue: bought from the gridBar by the house: the battery
Right now in the simulation
Loading weather, prices and use ...
Existing buildings

Existing buildings as proof

The office building and the house on the property use power today and can be measured. That is where theory can meet reality.